960 sft x 0 7 672 cfm minimum fan rating.
Pole barn roof vent fans. These fans work well in barns that use natural ventilation as well as mechanical ventilation to control indoor air quality levels. Make sure they are at least 11 feet high to prevent horse contact. This is especially important for naturally ventilated barns we recommend a 4 12 or 5 12 pitch. When researching an exhaust system figure 1 square foot of vent or inlet space for every 750 cfm fan capacity.
For farm buildings ventilation helps keep odor to a minimum and removes carbon dioxide for optimum animal health. Types of exhaust fans include shutter mounted wall exhaust fans boxed wall and slant wall exhaust fans. Ceiling fans that draw air up toward roof vents are one solution. We ll help you find the best solution.
The fan is constructed from 23 gauge galvanized steel for added strength and durability and it utilizes a unique black dome cover which provides uv protection. Next multiply the square feet of attic space by 0 7 to get the minimum number of cubic feet of air per minute the fan should be rated to move. Include overhangs in your building design. Broan s 355bk gable mount attic ventilator is a high quality ventilation system that s roof mounted and features a cover.
I am getting ready to insulate and heat an older pole barn so i have signed up here for some help and advice. I want to insulate and add a ceiling. Dear pole barn guru. Pole barn ventilation is one aspect of planning that you should spend some time considering.
It s pretty crude built. The amount of ventilation required varies based upon the utilization of the building. Consider a high roof pitch. Attic vent fans are commonly rated from 800.
The higher your roof pitch the more likely stale air will exhaust through the peak and fresh air will come through the eaves of your barn which enhances air quality. We have a wide selection of circulating panel ceiling and exhaust fans alongside accessories replacement parts and much more. The importance of pole barn ventilation can t be overstated. Ventilation ventilation is a necessary ingredient to aid in condensation control.
So i have an older pole barn that really has no eave soffit vents or ridge vents. If you need help trying to decide what barn fan is best for your needs call farmer boy s sales team at 800 845 3374. Add an additional 20 cfm x 1 20 if you have a steep roof and 15 cfm x 1 15 for a dark roof. My concern is condensation in the attic after insulating.